How do I communicate between my control systems?

Question:

We have a Data Highway+ network of Allen Bradley PLCs and have recently installed a Quantum DCS with Modbus TCP/IP. We would like to connect both systems together and display the data of both systems on an HMI. Is there a cheap and easy way to do this?

Answer by MatrikonOPC:

The short answer is: Yes, there is an easy way to do this. How? Using OPC the de facto standard for open data connectivity - an easy and inexpensive way to implement reliable bidirectional communications between your two control systems. The more detailed answer involves two pieces: OPC Servers to communicate with your specific controllers and an application that bi-directionally shares the data between them.

First, let’s look at getting the data to a common HMI: An OPC Server can provide you with access to all types of production data, regardless of whether the data comes from a real-time, historical, or alarm and event data source. Using the MatrikonOPC Universal Connectivity Server then, you can communicate to Allen Bradley PLCs and Quantum DCS, making their respective data available in a common OPC format that your HMI can display.

To share data directly between your two controllers requires that we establish bidirectional communication between both systems. The easiest way to do this is to use OPC Data Manager. OPC Data Manager is specifically designed to share real-time, historical, and Alarm & Events OPC data between two or more control systems in a secure and reliable manner. The interface is intuitive, making the mapping process quick and easy.

Please click here to get further details 'How do I communicate between my control systems?'

Zoom Lebron XII 12

How to Setup for wireless link between Modbus TCP and Modbus RTU

A solution is provided by ProSoft for Modbus TCP to Modbus RT using module RLX-IFH24E. Please click 'RLX-IFH24E' to further read this technical guide.

Zoom Kobe Elite High

How to Choose the Right Bus for Your Measurement System

National Instruments: When you have hundreds of different data acquisition (DAQ) devices to choose from on a wide variety of buses, it can be difficult to select the right bus for your application needs. Each bus has different advantages and is optimized for throughput, latency, portability, or distance from a host. This white paper examines the most common PC bus options and outlines the technical considerations to keep in mind when choosing the right bus for your measurement application.

To further read this article please click 'How to Choose the Right Bus for Your Measurement System'

NIKE AIR HUARACHE

Chevron Confirms Fire Incident on Rig Offshore Nigeria

SAN RAMON, Calif., January 16, 2011 – Chevron Corporation (NYSE: CVX) reports that its subsidiary, Chevron Nigeria Limited, is working to contain a fire that ignited early this morning aboard the K.S. Endeavor, a drilling rig offshore Nigeria operated by FODE Drilling Nigeria Limited. The rig was drilling a natural gas exploration well, located in the Funiwa Field approximately six miles (10 kilometers) offshore and in approximately 40 feet (12 meters) of water.

One hundred and fifty-four personnel were on the rig and an associated barge. Two contractors are still unaccounted for while all others are safe and undergoing medical examinations at an adjacent production platform. Aggressive search and rescue activities continue for the two missing personnel.

"Every effort is being made to find the missing workers. They are our utmost priority," said Andrew Fawthrop, managing director, Chevron's Nigeria/Mid-Africa Strategic Business Unit. "We do not know what caused the incident. We are working diligently to contain the fire, which is restricted to the rig. Substantial resources have been deployed including well control specialists and drilling experts. We continue to work in full cooperation with Nigerian authorities and are committed to providing additional information as it becomes known."

Nike Sportswear

Scada security presentation by InduSoft

A Technical guide on SCADA Security considerations. Please cLick 'Scada security presentation by InduSoft' to see the presentation.

Nike Air Jordan 1 Retro

Chevron Provides Update on Rig Incident Offshore Nigeria

SAN RAMON, Calif., January 17, 2012 – Chevron Corporation (NYSE: CVX) said that an extensive search and rescue effort continues for two contractors who remain missing after yesterday's fire aboard the K.S. Endeavor, a drilling rig offshore Nigeria operated by FODE Drilling Nigeria Limited. While Chevron's highest priority remains the rescue of the missing contractors, the company continues to devote the necessary resources to resolve the rig incident in a responsible and timely manner.

As previously reported, the K.S. Endeavor was drilling a natural gas exploration well for Chevron Nigeria Limited (CNL). The well is located in the Funiwa Field approximately six miles (10 kilometers) offshore and in approximately 40 feet (12 meters) of water.

Chevron reports that 152 workers on the rig and an associated barge were safely evacuated. They are now onshore and have been given medical examinations. Two remain hospitalized due to minor burns, while others are being held for further observation.

While a full investigation is still under way, Chevron said initial indications point to the possible failure of surface equipment during drilling operations that led to a loss of well control. The well continues to burn and the rig has partially collapsed. At this time, the company cannot estimate how long the fire will continue.

Puma Rihanna

Ichthys LNG Project Approves JGC/KBR/Chiyoda Joint Venture for EPC Contract

Chiyoda Corporation, JGC Corporation, and KBR jointly announced that INPEX Corporation and Total S.A., joint venture of Ichthys LNG project Australia, has approved award of the EPC Contract to the joint venture of formed by the JGC, KBR and Chiyoda for the construction of the downstream LNG facilities for the Ichthys LNG project Australia. The overall EPC Contract price for the project is expected to be US$ 15 Billion. The EPC Contract is the mix of Lump Sum Turn Key, Reimbursable and Remeasureable Contract scheme.

For further details on this project please click 'Ichthys LNG Project Approves JGC/KBR/Chiyoda Joint Venture for EPC Contract'

New Nike Air Max 2019

Emerging & Developing Economies Will Drive Automation Systems Market

(ARC Advisory Group) The Automation Expenditures for Discrete Industries market rebounded in 2010 after recovering from a deep global downturn in 2009. 2010 started out with sluggish order activity, which later escalated, resulting in a recovery in 2010 that was more robust than expected earlier in the year. Emerging economies, including the BRIC (Brazil, Russia, India, and China) countries, drove growth for the Automation Expenditure for Discrete Industries market in 2010, according to a new ARC Advisory Group study.

The second largest economy in the world, China, continues to be a growth driver for the overall automation business. Current activities reflect that China and India are still investing in automation. “Domestic demand will remain strong in emerging and developing economies. Consequently, the global automation systems market for discrete industries will experience moderate growth during the five year forecast period,” according to Senior Analyst Himanshu Shah, the principal author of ARC’s “Automation Expenditures for Discrete Industries Worldwide Outlook”.

Air Jordan XIV 14 Shoes

RadioLinx Industrial Frequency Hopping 900 MHz Ethernet

The RadioLinx Industrial Frequency Hopping 900 MHz Ethernet provides powerful and secure wireless Ethernet communications and is well suited for demanding, long-range (up to 30+ miles) SCADA and other Ethernet applications in tough environments. Operating in the license-free 900 MHz band, the RadioLinx Industrial Frequency Hopping 900 MHz Ethernet penetrates foliage and walls / ceilings better than higher frequency radios. The RLX-IFH9E is user configurable as a master, repeater and remote radio and employs the 128 bit AES encryption algorithm approved by the United States government for top secret information.

RadioLinx Industrial Frequency Hopping 900 MHz Ethernet radios are quickly and easily configured using the included, graphical ControlScape software. An OPC server software is also included and allows users to monitor radio network health with any OPC client based HMI software.

The RadioLinx ControlScape FH application provides a graphical representation of your RadioLinx Frequency Hopping radio network, allowing you to easily configure the radios and monitor their performance. ControlScape can be used to support configuration and installation as well as provide long-term monitoring of system performance.

For further details on this product please click 'RadioLinx Industrial Frequency Hopping 900 MHz Ethernet'

 

Neues in Alle